Sign In | Join Free | My himfr.com
Home > B&R Automation Plc >

X20AT4222 B&R X20 SYSTEM PLC I/O Module 4 Inputs For Resistance Temperature Measurement

Joyoung International Trading Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap X20AT4222 B&R X20 SYSTEM PLC I/O Module 4 Inputs For Resistance Temperature Measurement from wholesalers
     
    Buy cheap X20AT4222 B&R X20 SYSTEM PLC I/O Module 4 Inputs For Resistance Temperature Measurement from wholesalers
    • Buy cheap X20AT4222 B&R X20 SYSTEM PLC I/O Module 4 Inputs For Resistance Temperature Measurement from wholesalers
    • Buy cheap X20AT4222 B&R X20 SYSTEM PLC I/O Module 4 Inputs For Resistance Temperature Measurement from wholesalers
    • Buy cheap X20AT4222 B&R X20 SYSTEM PLC I/O Module 4 Inputs For Resistance Temperature Measurement from wholesalers

    X20AT4222 B&R X20 SYSTEM PLC I/O Module 4 Inputs For Resistance Temperature Measurement

    Ask Lasest Price
    Brand Name : B&R
    Model Number : X20AT4222
    Certification : COC
    Price : USD
    Payment Terms : T/T
    Supply Ability : 10EA
    Delivery Time : 3-5 days
    • Product Details
    • Company Profile

    X20AT4222 B&R X20 SYSTEM PLC I/O Module 4 Inputs For Resistance Temperature Measurement

    X20AT4222 B&R X20 SYSTEM PLC I/O Module 4 Inputs For Resistance Temperature Measurement

    MATERIAL NUMBER:

    X20AT4222

    DESCRIPTION:
    • 4 inputs for resistance temperature measurement
    • For PT100 and PT1000
    • Configurable sensor type per channel
    • Direct resistance measurement
    • Configurable 2- or 3- wire connections per module
    • Configurable filter time

    The module is equipped with 4 inputs for PT100/PT1000 resistance temperature measurement.

    Short description
    I/O module4 inputs for Pt100 or Pt1000 resistance temperature measurement
    General information
    B&R ID code0x1BA7
    Status indicatorsI/O function per channel, operating state, module status
    Diagnostics
    Module run/errorYes, using LED status indicator and software
    InputsYes, using LED status indicator and software
    Power consumption
    Bus0.01 W
    Internal I/O1.1 W
    Additional power dissipation caused by actuators (resistive) [W]-
    Certifications
    CEYes
    UKCAYes
    ATEXZone 2, II 3G Ex nA nC IIA T5 Gc
    IP20, Ta (see X20 user's manual)
    FTZÚ 09 ATEX 0083X
    ULcULus E115267
    Industrial control equipment
    HazLoccCSAus 244665
    Process control equipment
    for hazardous locations
    Class I, Division 2, Groups ABCD, T5
    DNVTemperature: B(0 - 55°C)
    Humidity: B(up to 100%)
    Vibration: B(4 g)
    EMC: B(bridge and open deck)
    LRENV1
    KRYes
    ABSYes
    EACYes
    KCYes
    Resistance measurement temperature inputs
    InputResistance measurement with constant current supply for 2- or 3-wire connections
    Digital converter resolution16-bit
    Filter timeConfigurable between 1 ms and 66.7 ms
    Conversion time
    1 channel20 ms with 50 Hz filter
    2 - 4 channels40 ms per channel with 50 Hz filter
    Conversion procedureSigma-delta
    Output formatINT or UINT for resistance measurement
    Sensor
    Sensor typeConfigurable per channel
    Pt100-200 to 850°C
    Pt1000-200 to 850°C
    Resistance measurement range0.1 to 4500 Ω / 0.05 to 2250 Ω
    Input filterFirst-order low-pass filter / cutoff frequency 500 Hz
    Sensor standardEN 60751
    Common-mode range>0.7 V
    Insulation voltage between channel and bus500 Veff
    Linearization methodInternal
    Measurement current250 µA ±1.25%
    Reference4530 Ω ±0.1%
    Permissible input signalShort-term max. ±30 V
    Max. error at 25°C
    Gain0.037%
    Offset0.0015%
    Max. gain drift0.004%/°C
    Max. offset drift0.00015%/°C
    Nonlinearity<0.001%
    Crosstalk between channels<-93 dB
    Temperature sensor resolution
    Pt1001 LSB = 0.1°C
    Pt10001 LSB = 0.1°C
    Resistance measurement resolution
    G = 10.1 Ω
    G = 20.05 Ω
    Common-mode rejection
    50 Hz>80 dB
    DC>95 dB
    Standardized range of values for resistance measurement
    G = 10.1 to 4500 Ω
    G = 20.05 to 2250 Ω
    Temperature sensor normalization
    Pt100-200.0 to 850.0°C
    Pt1000-200.0 to 850.0°C
    Temperature measurement monitoring
    Range undershoot0x8001
    Range overshoot0x7FFF
    Open circuit0x7FFF
    General fault0x8000
    Open inputs0x7FFF
    Resistance measurement monitoring
    Range overshoot0xFFFF
    Open circuit0xFFFF
    General fault0xFFFF
    Open inputs0xFFFF
    Electrical properties
    Electrical isolationChannel isolated from bus
    Channel not isolated from channel
    Operating conditions
    Mounting orientation
    HorizontalYes
    VerticalYes
    Installation elevation above sea level
    0 to 2000 mNo limitation
    >2000 mReduction of ambient temperature by 0.5°C per 100 m
    Degree of protection per EN 60529IP20
    Ambient conditions
    Temperature
    Operation
    Horizontal mounting orientation-25 to 60°C
    Vertical mounting orientation-25 to 50°C
    Derating-
    Storage-40 to 85°C
    Transport-40 to 85°C
    Relative humidity
    Operation5 to 95%, non-condensing
    Storage5 to 95%, non-condensing
    Transport5 to 95%, non-condensing
    Mechanical properties
    NoteOrder 1x terminal block X20TB12 separately.
    Order 1x bus module X20BM11 separately.
    Pitch12.5+0.2mm

    X20AT4222 B&R X20 SYSTEM PLC I/O Module 4 Inputs For Resistance Temperature Measurement


    Quality X20AT4222 B&amp;R X20 SYSTEM PLC I/O Module 4 Inputs For Resistance Temperature Measurement for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Joyoung International Trading Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)