Sign In | Join Free | My himfr.com
Home > B&R Automation Plc >

X20SI4100 B&R X20 PLC SYSTEM I/O Module 4 Type A Digital Inputs 4 Pulse Outputs 24 VDC

Joyoung International Trading Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap X20SI4100 B&R X20 PLC SYSTEM I/O Module 4 Type A Digital Inputs 4 Pulse Outputs 24 VDC from wholesalers
     
    Buy cheap X20SI4100 B&R X20 PLC SYSTEM I/O Module 4 Type A Digital Inputs 4 Pulse Outputs 24 VDC from wholesalers
    • Buy cheap X20SI4100 B&R X20 PLC SYSTEM I/O Module 4 Type A Digital Inputs 4 Pulse Outputs 24 VDC from wholesalers
    • Buy cheap X20SI4100 B&R X20 PLC SYSTEM I/O Module 4 Type A Digital Inputs 4 Pulse Outputs 24 VDC from wholesalers
    • Buy cheap X20SI4100 B&R X20 PLC SYSTEM I/O Module 4 Type A Digital Inputs 4 Pulse Outputs 24 VDC from wholesalers

    X20SI4100 B&R X20 PLC SYSTEM I/O Module 4 Type A Digital Inputs 4 Pulse Outputs 24 VDC

    Ask Lasest Price
    Brand Name : B&R
    Model Number : X20SI4100
    Certification : COC
    Price : USD
    Payment Terms : T/T
    Supply Ability : 10EA
    Delivery Time : 3-5 DAYS
    • Product Details
    • Company Profile

    X20SI4100 B&R X20 PLC SYSTEM I/O Module 4 Type A Digital Inputs 4 Pulse Outputs 24 VDC

    X20SI4100 B&R X20 PLC SYSTEM I/O Module 4 Safe Type A Digital Inputs, 4 Pulse Outputs, 24 VDC

    MATERIAL NUMBER:

    X20SI4100

    DESCRIPTION:
    • 4 safe digital inputs
    • 4 pulse outputs
    • Sink circuit
    • Software input filter configurable for each channel

    This module is equipped with 4 safe digital inputs. It is designed for a nominal voltage of 24 VDC.

    The module can be used to read various digital signals in safety-related applications up to PL e or SIL 3.

    The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line.

    This module is designed for X20 12-pin terminal blocks.

    X20SI4100 B&R X20 PLC SYSTEM I/O Module 4 Type A Digital Inputs 4 Pulse Outputs 24 VDC

    Short description
    I/O module4 safe type A digital inputs, 4 pulse outputs, 24 VDC
    General information
    B&R ID code0x1DBD
    System requirements
    Automation Studio3.0.71 or later
    Automation Runtime2.95 or later
    SafeDESIGNER2.58 or later
    Safety Release1.1 or later
    mapp Technology Packagemapp Safety 5.7.0 or later
    Status indicatorsI/O function per channel, operating state, module status
    Diagnostics
    Module run/errorYes, using LED status indicator and software
    InputsYes, using LED status indicator and software
    Blackout mode
    ScopeModule
    FunctionModule functionality
    Standalone modeNo
    Max. I/O cycle time800 µs
    Power consumption
    Bus0.32 W
    Internal I/O1.25 W
    Additional power dissipation caused by actuators (resistive) [W]0.6
    Electrical isolation
    Channel - BusYes
    Channel - ChannelNo
    Certifications
    CEYes
    Functional safetycULus FSPC E361559
    Energy and industrial systems
    Certified for functional safety
    ANSI UL 1998:2013
    Functional safetyIEC 61508:2010, SIL 3
    EN 62061:2013, SIL 3
    EN ISO 13849-1:2015, Cat. 4 / PL e
    IEC 61511:2004, SIL 3
    Functional safetyEN 50156-1:2004
    ATEXZone 2, II 3G Ex nA nC IIA T5 Gc
    IP20, Ta (see X20 user's manual)
    FTZÚ 09 ATEX 0083X
    ULcULus E115267
    Industrial control equipment
    HazLoccCSAus 244665
    Process control equipment
    for hazardous locations
    Class I, Division 2, Groups ABCD, T5
    DNVTemperature: A(0 - 45°C)
    Humidity: B(up to 100%)
    Vibration: A(0.7 g)
    EMC: B(bridge and open deck)
    LRENV1
    KRYes
    ABSYes
    EACYes
    KCYes
    Safety characteristics
    EN ISO 13849-1:2015
    CategoryCat. 3 when using individual input channels,
    Cat. 4 when using input channel pairs (e.g. SI1 and SI2) or more than 2 input channels
    PLPL e
    DC>94%
    MTTFD2500 years
    Mission timeMax. 20 years
    IEC 61508:2010,
    IEC 61511:2004,
    EN 62061:2013
    SIL CLSIL 3
    SFF>90%
    PFH / PFHd
    Per channel<1*10-10
    openSAFETY wiredNegligible
    openSAFETY wireless<1*10-14* Number of openSAFETY packets per hour
    PFD<2*10-5
    Proof test interval (PT)20 years
    I/O power supply
    Nominal voltage24 VDC
    Voltage range24 VDC -15% / +20%
    Integrated protectionReverse polarity protection
    Safe digital inputs
    Quantity4
    VariantType A
    Nominal voltage24 VDC
    Input characteristics per EN 61131-2Type 1
    Input filter
    Hardware≤150 μs
    SoftwareConfigurable between 0 and 500 ms
    Input circuitSink
    Input voltage24 VDC -15% / +20%
    Input current at 24 VDCMin. 2 mA to max. 4.59 mA. Hardware revision J0 and later: Min. 2 mA to max. 3.28 mA.
    Input resistanceMin. 5.23 kΩ, hardware revision J0 and later: Min. 7.33 kΩ
    Error detection time100 ms
    Insulation voltage between channel and bus500 Veff
    Switching threshold
    Low<5 VDC
    High>15 VDC
    Line length between signal source (pulse output or external signal) and inputMax. 60 m with unshielded line
    Max. 400 m with shielded line
    Pulse outputs
    Quantity4
    VariantPush-Pull
    Nominal output current100 mA, hardware revision J0 and later: 50 mA
    Output protectionThermal shutdown of all channels in the event of overload or short circuit,
    hardware revision J0 and later: Shutdown of individual channels in the event of overload or short circuit
    Peak short-circuit current300 mA, hardware revision J0 and later: 25 A for 15 µs
    Short-circuit current100 mAeff
    Leakage current when the output is switched off0.1 mA
    RDS(on)60 Ω
    Switching voltageI/O power supply minus voltage drop due to RDS(on)
    Total nominal current400 mA, hardware revision J0 and later: 200 mA
    Operating conditions
    Mounting orientation
    HorizontalYes
    VerticalYes
    Installation elevation above sea level0 to 2000 m, no limitation
    Degree of protection per EN 60529IP20
    Ambient conditions
    Temperature
    Operation
    Horizontal mounting orientation0 to 60°C
    Vertical mounting orientation0 to 50°C
    DeratingSee section "Derating".
    Storage-40 to 85°C
    Transport-40 to 85°C
    Relative humidity
    Operation5 to 95%, non-condensing
    Storage5 to 95%, non-condensing
    Transport5 to 95%, non-condensing
    Mechanical properties
    NoteOrder 1x safety-keyed terminal block separately.
    Order 1x safety-keyed bus module separately.
    Pitch25+0.2mm
    Quality X20SI4100 B&amp;R X20 PLC SYSTEM I/O Module 4 Type A Digital Inputs 4 Pulse Outputs 24 VDC for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Joyoung International Trading Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)