Sign In | Join Free | My himfr.com
Home > B&R Automation Plc >

X20AI4632 B&R X20 System PLC I/O Module 4 Analog Inputs ±10 V Or 0 To 20 MA

Joyoung International Trading Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap X20AI4632 B&R X20 System PLC I/O Module 4 Analog Inputs ±10 V Or 0 To 20 MA from wholesalers
     
    Buy cheap X20AI4632 B&R X20 System PLC I/O Module 4 Analog Inputs ±10 V Or 0 To 20 MA from wholesalers
    • Buy cheap X20AI4632 B&R X20 System PLC I/O Module 4 Analog Inputs ±10 V Or 0 To 20 MA from wholesalers
    • Buy cheap X20AI4632 B&R X20 System PLC I/O Module 4 Analog Inputs ±10 V Or 0 To 20 MA from wholesalers
    • Buy cheap X20AI4632 B&R X20 System PLC I/O Module 4 Analog Inputs ±10 V Or 0 To 20 MA from wholesalers

    X20AI4632 B&R X20 System PLC I/O Module 4 Analog Inputs ±10 V Or 0 To 20 MA

    Ask Lasest Price
    Brand Name : B&R
    Model Number : X20AI4632
    Certification : COC
    Price : USD
    Payment Terms : T/T
    Supply Ability : 10EA
    Delivery Time : 3-5 DAYS
    • Product Details
    • Company Profile

    X20AI4632 B&R X20 System PLC I/O Module 4 Analog Inputs ±10 V Or 0 To 20 MA


    X20AI4632 B&R X20 System PLC I/O Module 4 Analog Inputs ±10 V Or 0 To 20 MA


    MATERIAL NUMBER:

    X20AI4632

    DESCRIPTION:
    • 4 analog inputs
    • Either current or voltage signal possible
    • 16-bit digital converter resolution
    • Simultaneous input conversion
    • Very fast conversion time

    The module is equipped with 4 inputs with 16-bit digital converter resolution. It is possible to select between the current and voltage signal using different terminals.


    General information
    B&R ID code0x1BA1
    Status indicatorsI/O function per channel, operating state, module status
    Diagnostics
    Module run/errorYes, using LED status indicator and software
    InputsYes, using LED status indicator and software
    Channel typeYes, using software
    Power consumption
    Bus0.01 W
    Internal I/O1.5 W
    Additional power dissipation caused by actuators (resistive) [W]-
    Certifications
    CEYes
    UKCAYes
    ATEXZone 2, II 3G Ex nA nC IIA T5 Gc
    IP20, Ta (see X20 user's manual)
    FTZÚ 09 ATEX 0083X
    ULcULus E115267
    Industrial control equipment
    HazLoccCSAus 244665
    Process control equipment
    for hazardous locations
    Class I, Division 2, Groups ABCD, T5
    DNVTemperature: B(0 - 55°C)
    Humidity: B(up to 100%)
    Vibration: B(4 g)
    EMC: B(bridge and open deck)
    LRENV1
    KRYes
    ABSYes
    EACYes
    KCYes
    Analog inputs
    Input±10 V or 0 to 20 mA, via different terminal connections
    Input typeDifferential input
    Digital converter resolution
    Voltage±15-bit
    Current15-bit
    Conversion time50 μs for all inputs
    Output formatINT
    Output format
    VoltageINT 0x8001 - 0x7FFF / 1 LSB = 0x0001 = 305.176 µV
    CurrentINT 0x0000 - 0x7FFF / 1 LSB = 0x0001 = 610.352 nA
    Input impedance in signal range
    Voltage20 MΩ
    Current-
    Load
    Voltage-
    Current<400 Ω
    Input protectionProtection against wiring with supply voltage
    Permissible input signal
    VoltageMax. ±30 V
    CurrentMax. ±50 mA
    Output of digital value during overload
    Undershoot
    Voltage0x8001
    Current0x0000
    Overshoot
    Voltage0x7FFF
    Current0x7FFF
    Conversion procedureSAR
    Input filterHardware - Third-order low-pass filter / cutoff frequency 10 kHz
    Max. error
    Voltage
    Gain0.08%
    Offset0.01%
    Current
    Gain0.08%
    Offset0.02%
    Max. gain drift
    Voltage0.01%/°C
    Current0.01%/°C
    Max. offset drift
    Voltage0.001%/°C
    Current0.002%/°C
    Common-mode rejection
    DC70 dB
    50 Hz70 dB
    Common-mode range±12 V
    Crosstalk between channels<-70 dB
    Nonlinearity
    Voltage<0.01%
    Current<0.015%
    Insulation voltage between channel and bus500 Veff
    Electrical properties
    Electrical isolationChannel isolated from bus
    Channel not isolated from channel
    Operating conditions
    Mounting orientation
    HorizontalYes
    VerticalYes
    Installation elevation above sea level
    0 to 2000 mNo limitation
    >2000 mReduction of ambient temperature by 0.5°C per 100 m
    Degree of protection per EN 60529IP20
    Ambient conditions
    Temperature
    Operation
    Horizontal mounting orientation-25 to 60°C
    Vertical mounting orientation-25 to 50°C
    DeratingSee section "Derating".
    Storage-40 to 85°C
    Transport-40 to 85°C
    Relative humidity
    Operation5 to 95%, non-condensing
    Storage5 to 95%, non-condensing
    Transport5 to 95%, non-condensing
    Mechanical properties
    NoteOrder 1x terminal block X20TB12 separately.
    Order 1x bus module X20BM11 separately.
    Pitch12.5+0.2mm
    Quality X20AI4632 B&amp;R X20 System PLC I/O Module 4 Analog Inputs ±10 V Or 0 To 20 MA for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Joyoung International Trading Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)