Sign In | Join Free | My himfr.com
Home > B&R Automation Plc >

X67BC8321.L12 B&R X67 SYSTEM Bus Controller POWERLINK V1/V2 Controlled Node

Joyoung International Trading Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap X67BC8321.L12 B&R X67 SYSTEM Bus Controller POWERLINK V1/V2 Controlled Node from wholesalers
     
    Buy cheap X67BC8321.L12 B&R X67 SYSTEM Bus Controller POWERLINK V1/V2 Controlled Node from wholesalers
    • Buy cheap X67BC8321.L12 B&R X67 SYSTEM Bus Controller POWERLINK V1/V2 Controlled Node from wholesalers
    • Buy cheap X67BC8321.L12 B&R X67 SYSTEM Bus Controller POWERLINK V1/V2 Controlled Node from wholesalers
    • Buy cheap X67BC8321.L12 B&R X67 SYSTEM Bus Controller POWERLINK V1/V2 Controlled Node from wholesalers

    X67BC8321.L12 B&R X67 SYSTEM Bus Controller POWERLINK V1/V2 Controlled Node

    Ask Lasest Price
    Brand Name : B&R
    Model Number : X67BC8321.L12
    Certification : CE
    Price : USD
    Payment Terms : T/T
    Supply Ability : 10EA
    Delivery Time : 3-5 working days
    • Product Details
    • Company Profile

    X67BC8321.L12 B&R X67 SYSTEM Bus Controller POWERLINK V1/V2 Controlled Node

    X67BC8321.L12 B&R X67 SYSTEM Bus Controller POWERLINK (V1/V2) Controlled Node

    X67BC8321.L12 B&R X67 SYSTEM Bus Controller POWERLINK V1/V2 Controlled Node


    MATERIAL NUMBER:

    X67BC8321.L12

    DESCRIPTION:
    • POWERLINK
    • 16 digital channels, configurable as inputs or outputs
    • M12 connections
    • Integrated hub for efficient cabling
    • I/O configuration and firmware update via the fieldbus
    • Integrated connection to the local expansion via X2X Link for up to 250 additional modules
    • Configurable I/O cycle (starting at 200 ms)

    The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler.

    Additional X2X Link I/O nodes (X67 modules or other modules based on X2X Link) can be connected using the integrated X2X Link connection. Mechanically, POWERLINK is connected via an IP67-rated standard D-coded M12 Ethernet connector.

    POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org.


    Short description
    Bus controllerPOWERLINK (V1/V2) controlled node
    General information
    Inputs/Outputs16 digital channels, configurable as inputs or outputs using software, inputs with additional functions
    Insulation voltage between channel and bus500 Veff
    Nominal voltage24 VDC
    B&R ID code
    Bus controller0xA90E
    Internal I/O module0x1A1D
    Sensor/Actuator power supply0.5 A summation current
    Status indicatorsI/O function per channel, supply voltage, bus function
    Diagnostics
    OutputsYes, using LED status indicator and software
    I/O power supplyYes, using LED status indicator and software
    Connection type
    FieldbusM12, D-coded
    X2X LinkM12, B-coded
    Inputs/Outputs8x M12, A-coded
    I/O power supplyM8, 4-pin
    Power output15 W X2X Link power supply for I/O modules
    Power consumption
    Fieldbus4.2 W
    Internal I/O2.5 W
    X2X Link power supply24.3 W at maximum power output for connected I/O modules
    Certifications
    CEYes
    UKCAYes
    ATEXZone 2, II 3G Ex nA IIA T5 Gc
    IP67, Ta = 0 - Max. 60°C
    TÜV 05 ATEX 7201X
    ULcULus E115267
    Industrial control equipment
    HazLoccCSAus 244665
    Process control equipment
    for hazardous locations
    Class I, Division 2, Groups ABCD, T5
    EACYes
    KCYes
    Interfaces
    FieldbusPOWERLINK (V1/V2) controlled node
    TypeType 2
    Variant2x M12 interface (hub), 2x female connector on module
    Line lengthMax. 100 m between 2 stations (segment length)
    Transfer rate100 Mbit/s
    Transfer
    Physical layer100BASE-TX
    Half-duplexYes
    Full-duplexNo
    AutonegotiationYes
    Auto-MDI/MDIXYes
    Hub propagation delay0.96 to 1 µs
    Min. cycle time
    Fieldbus200 μs
    X2X Link200 μs
    Synchronization between bus systems possibleYes
    I/O power supply
    Nominal voltage24 VDC
    Voltage range18 to 30 VDC
    Integrated protectionReverse polarity protection
    Power consumption
    Sensor/Actuator power supplyMax. 12 W
    Sensor/Actuator power supply
    VoltageI/O power supply minus voltage drop for short-circuit protection
    Voltage drop for short-circuit protection at 0.5 AMax. 2 VDC
    Summation currentMax. 0.5 A
    Short-circuit proofYes
    Digital inputs
    Input characteristics per EN 61131-2Type 1
    Input voltage18 to 30 VDC
    Input current at 24 VDCTyp. 4 mA
    Input circuitSink
    Input filter
    Hardware≤10 μs (channels 1 to 4) / ≤70 µs (channels 5 to 16)
    SoftwareDefault 0 ms, configurable between 0 and 25 ms in 0.2 ms intervals
    Input resistanceTyp. 6 kΩ
    Additional functions50 kHz event counting, gate measurement
    Switching threshold
    Low<5 VDC
    High>15 VDC
    Event counters
    Quantity2
    Signal formSquare wave pulse
    EvaluationEach negative edge, cyclic counter
    Input frequencyMax. 50 kHz
    Counter 1Input 1
    Counter 2Input 3
    Counter frequencyMax. 50 kHz
    Counter size16-bit
    Gate measurement
    Quantity1
    Signal formSquare wave pulse
    EvaluationPositive edge - Negative edge
    Counter frequency
    Internal48 MHz, 3 MHz, 187.5 kHz
    Counter size16-bit
    Length of pause between pulses≥100 µs
    Pulse length≥20 µs
    Supported inputsInput 2 or input 4
    Digital outputs
    VariantCurrent-sourcing FET
    Switching voltageI/O power supply minus residual voltage
    Nominal output current0.5 A
    Total nominal current8 A
    Output circuitSource
    Output protectionThermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads, reverse polarity protection of the output power supply
    Diagnostic statusOutput monitoring with 10 ms delay
    Leakage current when the output is switched off5 µA
    Switching on after overload shutdownApprox. 10 ms (depends on the module temperature)
    Residual voltage<0.3 V at 0.5 A nominal current
    Peak short-circuit current<12 A
    Switching delay
    0 → 1<400 µs
    1 → 0<400 µs
    Switching frequency
    Resistive loadMax. 100 Hz
    Inductive loadSee section "Switching inductive loads".
    Braking voltage when switching off inductive loads50 VDC
    Electrical properties
    Electrical isolation
    Bus isolated from POWERLINK and channel
    Channel not isolated from channel
    Operating conditions
    Mounting orientation
    AnyYes
    Installation elevation above sea level
    0 to 2000 mNo limitation
    >2000 mReduction of ambient temperature by 0.5°C per 100 m
    Degree of protection per EN 60529IP67
    Ambient conditions
    Temperature
    Operation-25 to 60°C
    Derating-
    Storage-40 to 85°C
    Transport-40 to 85°C
    Mechanical properties
    Dimensions
    Width53 mm
    Height155 mm
    Depth42 mm
    Weight350 g
    Torque for connections
    M8Max. 0.4 Nm
    M12Max. 0.6 Nm
    Product Tags:

    X67BC8321.L12

      

    B&R X67 SYSTEM

      
    Quality X67BC8321.L12 B&amp;R X67 SYSTEM Bus Controller POWERLINK V1/V2 Controlled Node for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Joyoung International Trading Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)